Product Description
Variant: UPS Power Module (C).
The Uninterruptible Power Supply UPS Module (C) for Jetson Orin automatically powers Jetson Orin systems from batteries when the external supply fails. It is intended for Jetson Orin Nano or Jetson Orin NX installations that need to continue operating through a supply interruption. Communication uses I2C through pogo pins. Three separately purchased 21700 lithium batteries and a suitable external DC supply are required. With external power connected, the module can power the system and charge the batteries simultaneously.
Highlights
- Pogo pin connector for Jetson Orin series boards.
- Onboard lithium battery charging chip with dynamic power path management.
- Real-time monitoring of battery voltage, current, power and remaining capacity over I2C.
- Overcharge, overdischarge, overcurrent and short-circuit protection, with charge balancing and battery reverse-polarity indicators.
- Support for three 21700 batteries connected in series.
Technical Features
- Mounting hole compatibility: Jetson Orin Nano and Jetson Orin NX.
- Input voltage: 15 to 19 V DC.
- Output voltage with external power: equal to the input voltage.
- Output voltage on battery power: 9 to 12.6 V, equal to the battery voltage.
- Battery configuration: 3 × 21700 lithium batteries in series.
- Maximum charging current: approximately 1.33 A.
- Charging restart threshold: battery voltage below 12 V.
- Interfaces: I2C through pogo pins.
- Dimensions: 100 × 79 mm.
- Mounting hole size: 2.5 mm.
Application Areas
- A Jetson Orin Nano continues operating from batteries when external power fails.
- A Jetson Orin NX runs while its backup batteries are charged.
- Software monitors battery status over I2C to save files and shut down the system when voltage becomes low.
Notes
- The three 21700 batteries are not included; battery specifications must match the module.
- Observe correct polarity during charging and discharging and use suitable charging equipment. Improper lithium battery handling can cause fire and injury.
- Do not mix old and new batteries or different brands; check batteries for safe, stable operation before use.
- Replace batteries at their maximum cycle life or after more than two years of operation, whichever comes first.
- Keep batteries away from flammable or explosive materials and children.
What's Included
- 1 × UPS Power Module (C)
- 1 × Acrylic protection panel
- 1 × DC dual-plug cable
- 1 × Screws pack
Waveshare International Limited, World Trade Plaza south side, Fuhong Rd, Futian District, 518000 Shenzhen, China, [email protected], https://waveshare.com/